MDR-U6S
Rotorless Rheometer
1.Simple, quick installation.
2.Indicate test results as pass or fail using LEDs of different colors.
3.Great repeatability and reproducibility because of noise-resistance circuit and DFT algorithm.
4.New mechanical design to keep stable torque transmission.
5.Build in controller calculate and analyze the signal independently without computer.
6.Able to calibrate loss angle automatically.
7.It would not exceeding 2 min and 40 seconds when heating up from room temperature to the
equilibrium of 170℃±0.3℃
8.Time needed for changing temperature :
From 170℃ to 190℃ and reach the state of equilibrium 190℃±0.3℃.....within 55 seconds.
From 190℃ to 170℃ and reach the state of equilibrium 170℃±0.3℃.....within 1min and 40 seconds.
9.During testing, die chamber temperature will be redeemed to the tolerance of ±0.3℃ within 30±3 seconds from die closure.
10.By no means of overshooting nor of fluctuating, during recovering the test temperature, i.e., the
heating-up is carried out stably and gradually without fluctuation after die closure.
11.Key components are from US, Germany, and Japan.
2.Indicate test results as pass or fail using LEDs of different colors.
3.Great repeatability and reproducibility because of noise-resistance circuit and DFT algorithm.
4.New mechanical design to keep stable torque transmission.
5.Build in controller calculate and analyze the signal independently without computer.
6.Able to calibrate loss angle automatically.
7.It would not exceeding 2 min and 40 seconds when heating up from room temperature to the
equilibrium of 170℃±0.3℃
8.Time needed for changing temperature :
From 170℃ to 190℃ and reach the state of equilibrium 190℃±0.3℃.....within 55 seconds.
From 190℃ to 170℃ and reach the state of equilibrium 170℃±0.3℃.....within 1min and 40 seconds.
9.During testing, die chamber temperature will be redeemed to the tolerance of ±0.3℃ within 30±3 seconds from die closure.
10.By no means of overshooting nor of fluctuating, during recovering the test temperature, i.e., the
heating-up is carried out stably and gradually without fluctuation after die closure.
11.Key components are from US, Germany, and Japan.
Functions
1. In compliance with ISO 6502, ASTM D5289, JIS K6300-2, and GB/T 16584.
2. Provides various cure data and graphical curves.
For more detailed information please contact us: U-CAN DYNATEX INC.
#hardness testing #load testing machine #physical testing
#compression set #friction testing
2. Provides various cure data and graphical curves.
For more detailed information please contact us: U-CAN DYNATEX INC.
#hardness testing #load testing machine #physical testing
#compression set #friction testing